Change log ProAir Web

ProAir web 2011.12, 2012-01-13

  • Removed products:
    CVH
    SLA

 

ProAir web 2011.5, 2011-06-03   

  • New products:
    GRC, SWANa, LTAb
  • Data has been modified for the following products:
    ALCa, updated dimensions
    CVHb, new size
    LOCKZONE Ba, new size
    ALS, new version from ALSc to ALSd
    ROEa, new product code
  • Removed products:
    ARPa
    LOCKZONE Fa 1-125-30-RO
    LOCKZONE Fa 1-160-30-RO
    LOCKZONE Fa 1-200-30-RO
    LOCKZONE Fa 1-315-30-RO
    COLIBRI CCa 200-600-F
    COLIBRI CRa 200-600-F
    GRLc circular 

 

 

ProAir Web 2010.12, 15/12/2010

 

  • Software updates:
    Improved presentation for vertical supply
  • New products:
    FALCON Ca, PELICAN CEa HF, SWIFT Ca
  • Data adjustments for the following products:
    GRLc updated with sizes 100 and 125, COLIBRI CC, EAGLE C, HAWK and LOCKZONE updated with size 250-500
    EAGLE F version b updated, even for extract air
  • LOCKZONE Ba updated with size 200

ProAir Web 2008.11, 12/11/2008 

 

  • New products:
    ADAPT Ca, ADAPT Fa, ADAPT Sa, DOMOa 100
  • Data has been modified for the following products:
    EAGLE Fa, IRIS, ALCa

ProAir Web 2008.1, 29/1/2008 

 

  • New products
    CDHb, CLHb, DPGa + ALSc, IBIS Wa, IBIS + IBIS Ca, PELICAN CSa, PELICAN CEa-F, PELICAN CSa + ALSc, PELICAN CEA + ALSc-F, PELICAN CSa + ALSc-L, PELICAN CSa + ALSc-L-F, ROWb + ROWT2a, IRIS
  • Deleted products:
    GVL, GVL + TRG, LOCKZONE Fa-1, PMLc + ALSc, PMLc, PMTd + ALSC, DDKa, KRKa, KRKa + ALSc, LPKa 1 + ALSc, LPKa, 1LPKa 2 + ALSc, LPKa, 2LPVa + ALVc, PMUb, PMUb + ALSc, RDYa 1 + ALSc, RDYa, 1RDYa 2 + ALSc, RDYa, 2ROWb + ROWT1a, TDYc + ALSc, TDYc, TDYc K + ALSc, TDYc K, TRYa 2 + ALSc, TRYa 2, TRYa 2K + ALSc, TRYa 2, KTRYa 3 + ALSc, TRYa 3, TRYa 3K + ALSc, TRYa 3k, VDYc + ALVb, VOSa + ALVb, VRYc + ALVb

   

 

ProAir Web 2007.4, 24/4/2007   

 

  • New products:
    LOCKZONE F, EAGLE F, EAGLE S/D, HAWK C
  • Deleted products:
    TDY, TRY, CDY, RDY, LPC, LPK

ProAir Web 2006.10, 12/10/2006 

 

  • Data adjustments
  • Pictures of Colibri have been added

ProAir Web 2006.9, 15/09/2006 

 

  • Changed descriptions and updated data for ICP, IHC, IVC and CDY.
  • Drawing dimensions for ICP and IVC updated.
  • Changed to "Lp dB(A)" in all product diagrams.

ProAir Web 2006.8, 30/08/2006 

 

  • Maximum cooling capacity changed from 99999 W to 9999999 W.
  • Changed dimension data for LPA and sizes 160 and 400 has been added.

ProAir Web 2006.6, 14/06/2006  

 

  • Air flow direction turned 90 degrees for 2-way SRY.
  • EXC diagram changed
  • Exhaust air diffusers are transferred from MagiCAD to be able to calculate the correct sound levels.

ProAir Web 2006.4, 12/05/2006  

 

  • ”Checks to be made”, i.e. sound level, air velocity etc. is moved from the ”Automatic device selection” window to the ”Room description” window. It is now easier to change the check values when placing devices manually. 
  • Instead of max limits for airflow and cooling effect in the “Ventilation” window, there is now a warning if the calculation is unreliable.
  • Favourites are removed from the “Device position” window.
  • To calculate the total sound level, the exhaust devices will also be transferred from MagiCAD to ProAir web. NOTE that exhaust devices are not shown in ProAir web.
  • Room dimensions are not automatically set to default if you first have placed any device and want to change type of room in the “Room description” window.
  • When placing wall devices with ”Automatic device selection” it is possible to choose on which walls the devices should be placed.
  • There are now explanations to the blue and red line in the engineering graph under “Properties”.
  • Data in engineering graphs under “Properties” are given with the same room attenuation as in Swegon’s catalogue sheets.
  • On the printout, the sound level is given only at chosen damper positions. The text is also made clearer. 
  • Type of room is shown on the printout.
  • The sound level is calculated at 1,1 meter above the floor (1,8 m before).
  • Sound level for displacement units is calculated at a minimum distance of one meter from the loudest device when air flow is 70 l/s or less, otherwise at a minimum distance of two meters from loudest device.
  • Shown air velocity in effected area has been corrected.
  • Isovel picture for Condor has been corrected.

For more information se users manual.

 

  

 

ProAir web 2006.3, 09/03/2006  

 

  • The new LOCKZONE Ceiling has been added as supply air diffuser with "rotation spread" and as exhaust device. Note that LOCKZONE Ceiling also is available as low version.
  • The BOCa supply air terminal has been added. To run simulations in heating mode choose "Mixed" in the "Room description" window. The BOC is then available as a "Vertical ceiling device". Place the BOC at the right height with the "Positioning" feature. To run simulations in cooling mode choose "Displacement" in the "Room description" window. The BOC is then available as a low velocity terminal with "Circular spread". Place the BOC at the right height with the "Positioning" feature.