GLOBAL PX
The Swegon PX GLOBAL air handling units is a new series
of efficient and robust units, developed for installers valuing
simplicity, contractors that need to keep time and budget and
end-users who want the right indoor climate at the right cost.
- Integrated TAC5 controls
- Temperature efficiency, heat recovery up to 90%
- Air flows up to 6000 m³/h or 1670 l/s
- Cooling energy recovery
- For indoor and outdoor use
Size overview
GLOBAL |
PX |
05 |
  
|
GLOBAL |
PX |
08 |
   
|
GLOBAL |
PX |
10 |
    
|
GLOBAL |
PX |
12 |
     
|
GLOBAL |
PX |
13 |
       
|
GLOBAL |
PX |
14 |
          |
GLOBAL |
PX |
16 |
           |
GLOBAL |
PX |
18 |
             |
GLOBAL |
PX |
20 |
                 |
GLOBAL |
PX |
24 |
                    
|
|
|
|
|
1000 |
|
2000 |
|
3000 |
|
4000 |
|
5000 |
|
|
|
6000 |
|
|
|
(m³/h) |
|
|
|
|
|
|
|
|
|
|
277 |
|
555 |
|
833 |
|
1110 |
|
1390 |
|
|
|
1670
|
|
|
|
(l/s) |
|
|
|
|
|
|
Filtration

The directive EN16890 established a new classification system, based on particle matter (PM) and re-named the filters “ePM”. For product ranges GLOBAL RX, RX TOP, GLOBAL LP and GLOBAL PX, the selected fresh air bag filters have proven to be above par. Their classification “ePM1≥70%” is better than the required legal minimum.
ePM1
|
:
|
minimum 50% efficiency on 1 micron particles filtering
|
ePM2,5
|
:
|
minimum 50% efficiency on 2,5 micron particles filtering
|
ePM10
|
:
|
minimum 50% efficiency on 10 micron particles filtering
|
In our GLOBAL units, we use:
Supply air filters
|
:
|
ePM1≥70%
|
Extract air filters
|
:
|
ePM10≥50%
|
Counter-flow heat exchanger (PX)

The highly efficient, Eurovent certified counter-flow heat exchangers. They facilitate supply temperatures and permit or allow transfer of humidity between the two airflows. The exchangers are in “salt-air resistant” aluminium and are suitable for temperatures up to 80°C. They are compliant with the DIN1946 tightness standard and are Eurovent approved according to the EN 308 standard.
Counterflow plate heat exchangers consist of thin aluminium plates that form parallel air ducts arranged at opposite angles to one another. The warmer extract air heats the plates and transfers heat to the colder supply air. The contact surfaces are large because the air streams flow in parallel and in opposite directions. Temperature efficiency is >90 %. The supply air and extract air have completely separate air passages therefore any possible odours in the extract air cannot be transferred to the supply air. The heat exchanger does not recover moisture to supply air, which is good in facilities with high humidity levels. The heat exchangers er Eurovent certified.